Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Single Dryer Troubleshooting Guide

Will not

respond to handheld

PDA

Does PDA

respond to other

machines?

No

PDA has failed.

Yes

Check optic window for obstructions, dirt, or scratches.

If problem still exists replace control board

Will Not Keep

Time Of Day

During Power

Interruptions

Is a battery

 

 

 

Yes

installed?

 

 

 

 

 

No

A battery must be installed in order to keep time of day during power interruptions.

Does greater than

3.4VDC appear between the red and black wires of

the battery?

Yes

Check battery connector and termination

No

Replace Battery

If problem

persists, replace

control board.

No Decimal

 

 

 

 

 

Yes

 

Is Add coins mode

 

 

 

 

 

 

 

 

 

 

Point Is Used

 

 

 

 

 

 

 

 

selected?

 

 

 

 

 

In The Price

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dryer

Dries TooCheck for exhaust restriction

Slowly

Normal operation. Add coins mode

is used in some countries as needed based on local coin denominations.

Go to the section "Abnormal

Display Or Function"

If add coins mode is not desired, deselect

it in service mode.

24

16022904 Rev. 0

©2004 Maytag Appliances Company

Page 24
Image 24
Maytag MDE/MDG21PRA Will not Respond to handheld, Will Not Keep Time Of Day During Power Interruptions, No Decimal, Slowly