Troubleshooting Procedures

!W ARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Stack Dryer Diagnostic Code

d1 or d17

Door Sense Problem

d1 indicates the upper dryer door, d17 indicates the

lower dryer door on control board or due to power line

interference

Try to Clear the

 

 

 

 

 

 

 

diagnostic code by

 

 

 

 

 

 

False

pressing the

 

Did the

 

 

 

 

indication.

Delicates keypad

 

diagnostic code

 

Yes

 

 

Control board

 

 

 

for more than 1

 

clear?

 

 

 

 

is operating

 

 

 

 

 

second while the

 

 

 

 

 

 

normally.

code is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the control board.

No

If diagnostic code still appears, the power line is noisy

and should be

tested.

d4 or d20

Motor Control Circuit

Problem

Try to Clear the

diagnostic code by

pressing the

Delicates keypad

for more than 1 second while the code is displayed.

Push the Perm Press program keypad to start the diagnostic program.

 

 

 

 

 

 

False

Did the

 

 

 

 

indication.

diagnostic code

 

No

 

 

Control board

 

 

reappear?

 

 

 

 

is operating

 

 

 

 

 

 

 

 

 

 

normally.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

Check the wiring between the control board and the motor.

Fix the power line

disturbance.

 

 

Is the power

 

 

Yes

 

line supply to the

 

No

 

 

 

 

machine noisy?

 

 

 

 

 

Replace the

control board.

d5 Blocked Coin 1

(d13 Blocked Coin 2)

Or Coin Drop Circuit

Problem

Unplug dryer and check the wiring and termination between the coin drop and the control board.

Check for an

object blocking the

coin drop optic

sensor. It takes 8 seconds for the control to recognize the blockage.

If the problem still exists, replace the coin drop coin sensor.

If the

problem still exist, replace the control board.