Disassembly Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Remove Screws

4. Lift control panel away from the dryer.

Swing Out

and

Away

5.Remove two 5/16” screws holding coin drop mounting plate.

6.Remove two screws securing coin drop to mounting plate.

Remove

Two

Screws

Front Panel

1.Disconnect power to the machine.

2.Remove the Service Panel and Control Panel.

3.Remove two T-20H screws secured into lower flange of the upper Front Panel.

Remove Screws

4.Remove the two 5/16" hex head screws located in the top right and left front corners of the Front Panel.

Remove Screws

 

 

 

 