Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Single Dryer Diagnostic Code

d9

Voltage Problem

Less Than 90

VAC

Try to clear the

diagnostic code by

pressing the Delicates keypad for more than 1 second while the code is displayed.

Exit service mode , and pause for 10 seconds, enter service mode.

Did the

diagnostic code Yes cancel?

No

Low voltage was

sensed on the

power line, but is

now ok.

d12 Motor Sensed

Problem

Check installation to

 

 

 

 

 

insure proper power

 

 

 

 

Are other machines

going to this dryer. If

 

 

 

 

 

 

No

 

at this location giving a d9

d9 persist, check the

 

 

 

 

 

 

 

diagnostic code?

 

 

 

 

wiring or replace the

 

 

 

 

 

 

 

 

 

transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If problem persists replace

the control board.

Clear diagnostic

 

 

 

 

 

 

 

 

code by pushing a

 

Does

 

 

 

 

 

Delicates keypad

 

 

 

 

 

 

 

diagnostic code

 

 

 

Yes

 

for at least 1

 

 

 

 

 

 

remain?

 

 

 

 

 

second while code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check installation

 

 

 

to insure proper

Yes

 

 

 

 

power going to all

 

 

 

 

 

 

 

 

 

of the dryers

 

 

 

 

Replace control

board

False indication

control board

d16

Check wiring between debit

Is card reader

card reader

Power down and

up machine to

Replace card

reader or

PR Models Only

installed?

No

and control

board

reset card reader

control board.

Install reader call distributor to reset control

board. PDA will not reset board.

28

16022904 Rev. 0

©2004 Maytag Appliances Company

Page 28
Image 28
Maytag MDE/MDG21PND, MDE/MDG21PRA, MDE/MDG21PNA, MDE/MDG21PDA, MDE/MDG21PDD, MLE/MLG23PDF, MLE/MLG23PRA, MLE/MLG23PRF manual Vac