DRYER DIAGNOSTIC MODE

This mode is entered by depressing DELICATES for one second while in any of the set-up codes one through six (or while dAS displays if operating with Maytag Data Acquisition setup) or with a diagnostic code present. Diagnostic codes are cleared on entry and all display segments should flash. If a diagnostic code persists, it must be corrected before the diagnostic cycle may be executed.

All Single Load Models:

With all segments flashing, the diagnostic cycle is started by depressing the PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and 1 minute of cooldown. The WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. The DELICATES key pad will cancel this cycle and exit the diagnostic mode.

Stacked Models Only:

There are 2 procedures to initiate cycle activity from diagnostic mode for these models:

1.Upper Dryer Field Diagnostic Cycle – With the entire display flashing, the cycle is started by pressing the UPPER DRYER PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and one minute of cool down. The UPPER DRYER WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. Pressing the LOWER DRYER DELICATES key pad will cancel this cycle and exit the diagnostic mode.

2.Lower Dryer Field Diagnostic Cycle – With entire display flashing, the cycle is started by pressing the LOWER DRYER PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and one minute of cool down. The LOWER DRYER WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. Pressing the LOWER DRYER DELICATES key pad will cancel this cycle and exit the diagnostic mode.

Dryer Help Mode

The Help Mode is entered by pressing the Whites & Colors keypad while in special pricing option, step 2.XX (or while dAS displays if operating with Maytag Data Acquisition set up). In help mode, the software revision is displayed in the digits. Press the Whites & Colors key at anytime to exit help mode.

In help mode, other display symbols and elements are mapped to reflect the state of various input and outputs as follows:

 

Single Load Dryers

DISPLAY

 

DESCRIPTION

*

 

Low voltage present (below 90VAC)

Circle above digit

 

Door closed

&

 

140° thermostat closed

OR

 

Motor sensed running

AIR

 

Heater/gas valve relay on

FLUFF

 

Motor relay on

 

 

 

Stacked Dryer Models

Upper Dryer Only – Upper Half Of Display

 

Upper dryer motor sensed running

Circle above digit

Upper dryer door closed

COOL

Upper dryer 140° thermostat closed

OR

Upper dryer heater relay on

&

Upper dryer motor relay on

 

 

Lower Dryer Only

– Lower Half Of Display

*

Low voltage present (below 90VAC)

 

Lower dryer motor sensed running

Circle above digit

Lower dryer door closed

COOL

Lower dryer 140° thermostat closed

OR

Lower dryer heater relay on

&

Lower dryer motor relay on