Replacing the Light-Source Lamp

Replacing the Light-Source Lamp

Projecting after the lamp has been used for more than 1000 hours (LIGHT OUTPUT CONTROL MODE) (LAMP POWER CONTROL MODE)

Accumulated used hours of the light-source lamp

1000 hours

1900 hours

2000 hours

2010 hours

When the lamp use time reaches 1000 hours:

“1000h” and “Lamp replacement” appear on the screen.

*The messages will disappear when any button is pressed.

*The time after which the display appears can be set with the OSD menu.

When the lamp use time exceeds 1900 hours:

The LAMP indicator blinks on the projector. “Lamp replacement” appears on the screen.

*To cancel this message, press the EXIT button or display another menu.

Every time the projector is turned on, the message appears.

When the lamp use time exceeds 2000 hours:

The LAMP indicator blinks on the projector.

“Lamp replacement” appears on the screen and the word “Warning” blinks.

*To cancel this message, press the EXIT button. However, the same message will appear every hour.

*If the projector is put in stand-by mode or turned off after the lamp has been used for more than 2000 hours, it can not be turned back on again unless the light-source lamp is replaced with a new one.

(If the projector is not put in stand-by mode or turned off, it can be used until 2010 hours is reached.)

Replace with a new lamp (lamp unit) and reset the lamp time. (Refer

to page 62.)

When the lamp use time reaches 2010 hours:

The projector is forcibly turned off.

The LAMP and OPERATE indicators blinks on the projector.

*The projector can not be turned on unless the lamp (lamp unit) is replaced with a new one and the lamp time is reset. (Refer to page 62.)

1000 h

Lamp replacement

EXIT

Lamp replacement

EXIT

Warning

Lamp replacement

EXIT

CAUTIONS

If the projector is set up in a constricted place which is unsuitable for work, and if you perform replacement work there, this could cause injury. Move the projector to a place large enough for work, and then replace the light-source lamp.

Use a genuine product for the light-source lamp. If you use other than a genuine product, this could cause a malfunction. Also, never use an old light-source lamp. This could cause marked degradation in performance or explode, possibly causing the projector to malfunction or broken pieces to injure you.

Do not replace the light-source lamp immediately after the projector has been used. The temperature of the light-source lamp is still high and could cause a burn. Allow a cooling period of one hour or more before performing replacement.

Before starting light-source lamp replacement work, turn off the MAIN POWER switch, and disconnect the power cord from the wall outlet. If you perform the replacement work with the power cord connected, this could cause injury or electric shock.

The light-source lamp used in this projector is a high pressure mercury lamp. Be careful when disposing of the light-source lamp. If anything is unclear, please consult your dealer.