Miller Electric Auto Axcess 675 manual Touch Sensor Operation, Remote Program Select

Models: Auto Axcess 675

1 68
Download 68 pages 22.37 Kb
Page 25
Image 25

3-14. Touch Sensor Operation

The touch sensor feature allows the robot to locate a weldment using the wire feed system and welding power source. The weld output terminals provide a path for touch sensor voltage when this feature is turned on at the peripheral receptacle. Turning on touch sensor causes a dc voltage to be present on the welding wire. When welding wire touches the weldment, the voltage sensing circuit closes, and a +24 volts dc output signal is sent to the robot control indicating weldment detection. Touch sensor dc voltage on the welding wire is 80 volts DC. As soon as touch sensor turns on, WIRE LIVE appears on the front panel display.

3-15. Remote Program Select

.Remote Program Select is factory set to “On”. WaveWriter or File Management software is required to turn this function “Off”.

When Remote Program Select is On, a remote device or robot pendant may be used to select programs. When Off, program selection must be done from the welding power source front panel.

3-16. Remote Program Setting

.When Remote Program Select is “On”, program selection will be determined by remote input once a weld is initiated. Prior to welding, program selection can be done in a normal manner from the welding power source front control panel.

See the following table for the remote program select binary code.

Program No.

Output A

Output B

Output C

 

 

 

 

1

Off

Off

Off

 

 

 

 

2

On

Off

Off

 

 

 

 

3

Off

On

Off

 

 

 

 

4

On

On

Off

 

 

 

 

5

Off

Off

On

 

 

 

 

6

On

Off

On

 

 

 

 

7

Off

On

On

 

 

 

 

8

On

On

On

 

 

 

 

OM-201 540 Page 21

Page 25
Image 25
Miller Electric Auto Axcess 675 manual Touch Sensor Operation, Remote Program Select, Remote Program Setting