4-7. Reset Mode

RST

NO

Enter reset mode by turning power On and pressing the Program Push Button until the RST NO message is displayed. RST NO message will not display until after the power-up sequence is completed (approximately 20 seconds).

.Reset mode is not active when Program Lock is enabled.

The reset mode allows the operator to reload factory program settings for all eight active programs in the unit.

.System configuration data will be lost during the Reset operation.

RST

YES

RST

YES

CYCL

PWR

Rotate Adjust knob to change NO

to YES.

Press the Arc Control button to

confirm the reset.

The reset message is displayed for 2 seconds while factory program settings are being reloaded.

During the reset mode the following factory default programs are loaded into the unit:

Cycl Pwr message appears on the display

when programs complete loading.

Turn power off, wait 10 seconds, and turn power back on again to complete the reset operation.

.After Reset is complete, be sure to load appropriate programs that contain the correct wire size, process, and shielding gas for the welding operation

Program 1

Pulse

 

.035 Mild Steel

 

90% Argon, 10% CO2

Program 2

MIG

 

.035 Mild Steel

 

75% Argon, 25% CO2

Program 3

Accu-pulse

 

.035 Mild Steel

 

90% Argon, 10% O2

Program 4

Pulse

 

.045 Mild Steel

 

90% Argon, 10% CO2

Program 5

MIG

 

.045 Mild Steel

 

75% Argon, 25% CO2

Program 6

Accu-pulse

 

.045 Mild Steel

 

90% Argon, 10% O2

Program 7

Pulse

 

.052 Mild Steel

 

90% Argon, 10% CO2

Program 8

MIG

 

.052 Mild Steel

 

75% Argon, 25% CO2

198 993 / 803 246-B

OM-201 540 Page 30

Page 34