Sample Auto-Calibration Routine For Fanuc Robot

1: Call Safehome

2: J P[1] 40% Fine

Arcstart [10.0Volts, 100.0IPM] 3: L P[2] 10.0 sec Fine

Arc End [0.0Volts, 0.0IPM, 0.0Sec] 4: Wait 1.00 (Sec)

5: J P[3] 40% Fine

Arcstart [44.0Volts, 1000.0IPM] 6: L P[4] 10.0 sec Fine

Arc End [0.0Volts, 0.0IPM, 0.0Sec] 7: Call Safehome

Sample Auto-Calibration Routine For ABB Robot

Move J home, v500, z50, tweldgun;

Arcl \ on, *, v500, sm1, wd1, wv0, z50, tweldgun;

Arcl \ off, *, v500, sm1, wd1, wv0, z50, tweldgun;

WaitTime 5;

Arcl \ on, *, v500, sm1, wd2, wv0, z50, tweldgun;

Arcl \ off, *, v500, sm1, wd2, wv0, z50, tweldgun;

Move J home, v500, z50, tweldgun;

*Seam Data values must all be set at zero.

Weld Data 1:

Weld Data 2:

 

 

weld_sched:=0

weld_sched:=0

 

 

weld_speed:=5

weld_speed:=5

 

 

weld_voltage:=10

weld_voltage:=44

 

 

weld_wfs:=100

weld_wfs:=1000

 

 

org_weldspeed:=0

org_weldspeed:=0

 

 

org_weldvoltage:=0

org_weldvoltage:=0

 

 

org_weldwfeed:=0

org_weldwfeed:=0

 

 

OM-201 540 Page 29

Page 33
Image 33
Miller Electric Auto Axcess 675 manual Sample Auto-Calibration Routine For Fanuc Robot, Weld Data