Miller Electric Auto Axcess 675 manual User Interface Module PC7 Diagnostic LED’s

Models: Auto Axcess 675

1 68
Download 68 pages 22.37 Kb
Page 44
Image 44

7-8. User Interface Module PC7 Diagnostic LED’s

2

3

LED1

LED2

1

1 User Interface Module PC7

Diagnostic LED’s are visible inside unit, located on PC7 mounted behind the front panel.

Refer to Section 7-9for information on diagnostic LED’s.

Reinstall cover after checking diagnostic LED’s.

2Dip Switch S1

3Dip Switch S2

218 559-A / 803 300-A

Dip switches are used to identify each circuit board on the internal network. Dip switch settings are different for each circuit board. For proper operation, do not change dip settings from those shown.

7-9. Diagnostic LED’s On User Interface Module PC7

LED

 

Status

Diagnosis

 

 

 

 

1, 2

 

On

See Network Status Table in Section 7-12

 

 

 

 

 

 

Off

See Network Status Table in Section 7-12

 

 

 

 

OM-201 540 Page 40

 

 

Page 44
Image 44
Miller Electric Auto Axcess 675 User Interface Module PC7 Diagnostic LED’s, Diagnostic LED’s On User Interface Module PC7