4-1 . Operational Terms (Continued)

Start

Provides voltage/arc adjust, wire feed rate, and time value for modified arc starts (only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software).

Weld

Sequence function that allows for a timed weld operation [(0 to 999 seconds) only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software].

Crater

Allows setting of voltage/arc adjust, wire feed rate, and time value for arc ends (only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software).

Postflow

Setting a time value for gas flow after arc end (only available on Auto Axcess models in the Arc On and Analog

 

input or the Arc On and No Analog input modes, and can only be set with the optional PDA with File Manage-

 

ment software).

Retract

Sequence function that allows the wire to move back towards the contact tip when a welding operation is

 

completed. Setting is both speed (IPM) and time (sec), (only available on Auto Axcess models in the Arc On

 

and Analog input or the Arc On and No Analog input modes, and can only be set with the optional PDA with File

 

Management software).

Auto Thread

Method of jogging wire without holding jog or trigger switch. Pressing Jog and Retract simultaneously will

 

automatically feed wire. Default setting is 72 inches at a feed rate of 700 ipm. Pressing jog, purge, or trigger

 

switch will terminate the auto-threading feature. These values can be changed using a PDA with File

 

Management/WaveWriter software.