.A complete Parts List is available on-line at www.MillerWelds.com

4-3. Work Cable Routing Inside Unit

2

1Work Cable

2Output Terminal Block

Insert work cable through opening in front panel and route along back of front panel to output terminal block.

1Close door.

 

 

 

Ref. 802 982-A

4-4. Process/Polarity Table

 

 

 

 

 

 

Process

Polarity

Cable Connections

 

 

 

 

Cable To Gun

Cable To Work

 

 

 

 

GMAW − Solid wire with shield-

DCEP − Reverse polarity

Connect to positive (+) out-

Connect to negative (−) output

ing gas

 

put terminal

terminal

 

 

 

 

FCAW − Self-shielding wire −

DCEN − Straight Polarity

Connect to negative (−)

Connect to positive (+) output

no shielding gas

 

output terminal

terminal

 

 

 

 

4-5. Changing Polarity

1

.Connection hardware must be tightened with proper tools. Do not just hand tighten hardware. A loose electrical connection will cause poor weld performance and excessive heating at the terminal block.

C H A N G IN G P O L A R IT Y

DCEP

DCEN

ElectrodePOSITIVEPositive

Electrode Negative

FOR SOLID WIRE

Flux Core Wire

WorkClamp

WorkClamp

Lead

 

Lead

2

Wire Drive

Wire Drive

Lead

Lead

1Lead Connections For Direct Current Electrode Positive (DCEP)

2Lead Connections For Direct Current Electrode Negative (DCEN)

Always read and follow wire manufacturer’s recommended polarity, and see Section 4-4.

Close door.

Ref. 203 501 / Ref. 802 982-

OM-225 311 Page 13

Page 17
Image 17
Miller Electric M-10 Gun, 180, 140 Auto-Set Work Cable Routing Inside Unit, Process/Polarity Table, Changing Polarity