Miller Electric M-10 Gun, 180, 140 Auto-Set manual Do not move or operate unit where it could tip

Models: 140 Auto-Set 140 M-10 Gun 180

1 60
Download 60 pages 42.01 Kb
Page 20
Image 20

.A complete Parts List is available on-line at www.MillerWelds.com

4-8. Selecting A Location And Connecting Input Power For 230 VAC Model

18 in (457 mm) of space for airflow

Y Do not move or operate unit where it could tip.

1

6

=GND/PE Earth

 

 

Ground

 

8

 

5

 

7

 

2

3

L1

 

L2

 

4

1

9

10

L2 L1

YInstallation must meet all Na- tional and Local Codes − have only qualified persons make this installation.

YDisconnect and lockout/tag- out input power before con- necting input conductors from unit.

YAlways connect green or green/yellow conductor to supply grounding terminal first, and never to a line termi- nal.

1 Rating Label

Supply correct input power.

2Black And White Input Conductor (L1 And L2)

3Green Or Green/Yellow Grounding Conductor

4Input Power Cord.

5Disconnect Device (switch shown in the OFF position)

6Disconnect Device Grounding Terminal

7Disconnect Device Line Terminals

Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.

Connect input conductors L1 and L2 to disconnect device line terminals.

8 Over-Current Protection

Select type and size of over-current protection using Section 4-9(fused disconnect switch shown).

Close and secure door on disconnect device. Remove lockout/tagout de- vice, and place switch in the On posi- tion.

9Plug (NEMA 6-50P)

10Receptacle (NEMA 6-50R)

Connect plug to receptacle.

YSpecial installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.

230 VAC, 1

Tools Needed:

Ref. 804 681-A / Ref. 802 443 / Ref. 802 085 / 803 766-B

OM-225 311 Page 16

Page 20
Image 20