.A complete Parts List is available
SECTION 5 − OPERATION
5-1. Controls For 115 VAC Model w/Auto-SetE
1
6
2
3
54
227
1 Wire Speed Control
Turn control clockwise inside white scale
2 Voltage Control
Turn control clockwise inside white scale
3Power Switch
4Over Temperature Light
5Gun Trigger Receptacle
6Auto−Set™ Light
To use Auto−Set™ mode, rotate Wire Speed control inside blue area for the applicable Weld Wire Diameter, Auto−Set™ light will turn on, and the unit will
provide the appropriate wire feed speed for the material thickness selected using the Voltage control (see Section
Rotate Voltage control inside blue scale (24 ga to 1/8”) for the applicable material thickness and the unit will provide the appropriate voltage within the range of the selected material thickness and the selected Weld Wire Diameter (see Section