.A complete Parts List is available on-line at www.MillerWelds.com

5-6. Weld Parameter Chart For 115 VAC Model w/Wire Speed Tracking Mode

Refer to chart below to select Voltage and Wire Speed based on thickness of material being welded.

1. Number on left of

2. Number on right

slash is Voltage

of slash is Wire

Knob Setting.

Speed Knob Setting.

(Example: 4.5/65)

(Example: 4.5 / 65)

Solid Wire ER70S−6 (DCEP)

Solid Wire ER70S−6 (DCEP)

Flux Core E71T−11 (DCEN)

Stainless Steel (DCEP)

To enable wire speed tracking, proceed as follows:

1.Turn Power switch off.

2.Rotate Voltage knob to minimum.

3.Rotate Wire Speed knob to maximum.

4.Hold gun trigger in while turning on Power switch.

.To verify wire speed tracking is on, open drive roll pressure arm, pull trigger, and rotate Voltage knob from min. to max. Drive roll speed will change rpm if tracking is on.

OM-225 311 Page 30

Page 34
Image 34
Miller Electric 180, M-10 Gun, 140 Auto-Set manual OM-225 311