Four-Channel Digital Video Recorder

NOTE: You cannot use spot monitor output and VGA output at the same time.

NOTE: Set the CVBS or VGA selector switch before turning on the DVR. You cannot change the setting while the unit is running.

Connecting the Monitor

Connecting the Spot Monitor

Figure 7 — Video Out connectors.

Connect the SPOT monitor to the Video Out connector.

NOTE: For SPOT monitor Output, set the CVBS/VGA selector switch to the CVBS.

Connecting the RGB Monitor

Figure 8 — VGA connector.

A VGA port is provided for RGB monitor output. Connect the RGB monitor to the VGA connector if required. Connect an RGB cable with a DB-15 (male) connector, which is usually less than 10 feet, to the DVR connector.

NOTE: For RGB monitor output, set the CVBS/VGA selector switch to the VGA.

Connecting Alarms

Figure 9 — Alarm Input connector strips.

NOTE: To make connections on the Alarm Connector Strip, press and hold the button and insert the wire in the hole below the button. After releasing the button, tug gently on the wire to make certain it is connected. To disconnect a wire, press and hold the button above the wire and pull out the wire.

5

Page 15
Image 15
Mitsubishi Electronics DX-TL4U manual Connecting the Monitor, Connecting Alarms, Connecting the Spot Monitor