Mitsubishi Electronics DX-VS1 user manual state may happen

Models: DX-VS1

1 38
Download 38 pages 14.84 Kb
Page 36
Image 36
state may happen.

state may happen.

Q. When a fire wall is in a network, can you install DX-VS1UE and can operate it?

A. In order for DX-VS1UE to transmit data and a picture, the default port number of 80th and 8080th needs to be vacant.

However, usually only the 80th port is vacant in the network with a fire wall because of se- curity. In this case, a user can change a picture transmission port into the other port which can pass fire walls from 8080th.

A user can set up on Customizing Page of Server Configuration Page.

Q. How can a user monitor the image transmitted from DX-VS1UE?

A. A user can see the real-time image of DX-VS1UE using 5 or later versions of Internet Explorer. It is necessary to install the DX-VS1UE ActiveX control for Internet Explorer at this time. This ActiveX control is used on the page (Simple Viewer Page, DVR Configura- tion Page, Pan/tilt/zoom Control Page, etc.) where a user monitors an image.

When the ActiveX (DX-VS1UE Control) is already installed, it can delete and install.

Q. If the ActiveX is not installed properly, what should I do?

A. Depending on the kind of computer, the ActiveX Control (the DX-VS1UE control pro- gram) may not be installed appropriately. In this case, Any image cannot be seen or a mes- sage “No input” is displayed. In order to solve this problem, please remove the DX-VS1UE control program as follows, and re-install.

The DX-VS1UE control program is installed in C:\windows\Downloaded Program Files in case of Windows 98 or Windows Me. In case of Windows NT or Windows 2000, it is in- stalled in C:\winnt\Downloaded Program Files.

Please put the mouse cursor on the DX-VS1UE control program, click the right button, and choose remove menu.

When you access DX-VS1UE once again, the DX-VS1UE control program will be in- stalled.

Q. When the ActiveX causes an error at the time of execution, how can I solve the prob- lem?

A1. In case a message box like “Mismatched Version” is displayed, please do the following.

The ActiveX in DX-VS1UE is re-installed.

A2. In case a message box like “DX-VS1UE client initializing failed” is displayed, please do the following.

The Winsock2 library is not installed. The Winsock2 library for Windows 95/98 can be downloaded from a public site. Please install Winsock2 in your system after download, and restart your browser.

Q. The image of DX-VS1UE is not displayed. What is the problem?

A. There is the possiblility that BNC cable is not connected appropriately. If the cable is connected appropriately, connection of DX-VS1UE and an external Pan/tilt/zoom camera may be unstable. Please check the connection of the BNC cable, or whether the BNC cable

35

DX-VS1UE User’s Manual

Page 36
Image 36
Mitsubishi Electronics DX-VS1 user manual state may happen