Mitsubishi Electronics Refrigerant System Diagram, PKH18FL PKH24FL PKH30FL PKH36FL, Unit inch

Models: PKH24FL PKH30FL PKH18FL PKH36FL

1 53
Download 53 pages 36.16 Kb
Page 18
Image 18
Remote controller

Remote controller

WIRELESS REMOTE CONTROLLER

2-9/32

COOL CHECK

TEST

˚F

MODEL

RUN

˚C

DRY SELECT

 

STOP AMPM

AUTO FAN

SWING

 

FAN

START AMPM

 

HEAT NOT AVAILABLE

 

ON/OFF REFRIGERANT SYSTEM DIAGRAMTEMP

6-3/8

Unit : inch

3/4

6

REFRIGERANT SYSTEM DIAGRAM

PKH18FL

PKH24FL

PKH30FL

PKH36FL

 

 

Refrigerant pipe

 

 

(option)

 

 

{5/8"

 

 

(with heat insulator)

 

 

Flared connection

 

Strainer

 

Pipe temperature

Restrictor

Refrigerant pipe

thermistor / Liquid

(option)

valve

(RT2)

{3/8"

 

Distributor

(with heat insulator)

 

 

 

Capillary tube

Flared connection

 

 

 

PKH18FL : ({0.126x{0.071x19.7)

 

PKH24FL : ({0.157x{0.079x19.7) w

 

 

Refrigerant pipe

 

 

(option)

 

 

{3/4"

 

 

(with heat insulator)

 

Strainer

Flared connection

 

 

Pipe temperature

Restrictor

Refrigerant pipe

thermistor / Liquid

(option)

(RT2)

valve

{1/2"

Distributor

 

(with heat insulator)

Flared connection

Capillary tube

PKH30FL : ({0.157x{0.079x23.6)

PKH36FL : ({0.157x{0.079x15.7)

Refrigerant flow

HEATING

COOLING

wAn error in this diagram has been modified. The size of capillary tube {0.157x{0.07x19.7, was wrong.