2-5 Auto vane control

˚F

AUTO

FAN

SWING

AM

ON/OFF TEMP

 

FAN

AUTO STOP

MODE

VANE

AUTO START

CHECK

LOUVER

h

TEST RUN

 

min

SET

RESET CLOCK

<How to operate>

To change the air flow direction, press VANE ( ) button.

1

2

3

4

5

10˚

30˚

60˚

70˚

SWING

<Remote controller display>

1 10°

2 30°downward

3 60°downward

4 70°downward

5 SWING

Changes by pressing the AIR DISCHARGE button.

Available in COOL operation with fan speed on HIGH or in HEAT operation.

Unavailable in DRY operation.

If fan speed changes from LOW to HIGH during 30° downward discharge in COOL mode, the direction auto- matically changes to 10°.

(1) COOL/DRY operation

At the start-up of COOL or DRY operation, the discharge direction in automatically set to 10°. After, it can be changed to

another direction with VANE ( ) button on the remote controller.

<Auto return>

When discharge 60° or 70° continues for 1 hour with the fan speed at LOW, the discharge direction turns to the horizontal discharge automatically.

After that, 60° or 70° is available by setting with the remote controller, and it continues for 1 hour.

If the discharge direction changes from 60° or 70°, the direction returns to the horizontal discharge when 1 hour has passed since the discharge 60° started.

If the discharge direction changes from 60° (or 70°) to the horizontal discharge, the 1-hour timer to return the horizontal discharge is cancelled.

(2) HEAT operation

At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.

After, it can be changed to another direction with VANE ( ) button. The discharge direction shifts to 10° regardless of the remote controller settings under any of the following conditions.

Thermostat OFF

Defrosting

Indoor fan speed LOW in hot adjustment

35