| ˚F | <How to operate> | |
AUTO |
|
| 1 Press POWER ON/OFF button. | |
FAN | AM | |||
|
| 2 Press the MODE button to display “AUTO” | ||
|
|
| ||
ON/OFF | TEMP | 3 Press the TEMP( or ) button to set the desired temperature. | ||
|
|
| ||
|
|
| NOTE: The set temperature changes 2°F when the TEMP( or ) | |
| FAN | AUTO STOP | button is pressed one time. | |
MODE | VANE | AUTO START | Automatic 65 to 83°F. | |
●“AUTOMATIC” works to change by itself the operation | ||||
CHECK | LOUVER | h | ||
mode either to cooling or heating according to the room | ||||
TEST RUN |
| min | ||
| temperature. | |||
|
|
| ||
SET | RESET CLOCK |
|
(1)Initial mode
1 When AUTO operation starts after unit OFF.
●If the room temperature is higher than the set temperature, operation starts in COOL mode.
●If the room temperature is equal to or lower than the set temperature, operation starts HEAT mode. 2 When AUTO operation starts after COOL or HEAT operation, the previous mode continues.
(2 ) Mode change
1HEAT mode changes to COOL mode when 15 minutes have passed since the room temperature became 4 degrees
above the set temperature.
2COOL mode changes to HEAT mode when 15 minutes have passed since the room temperature became 4 degrees below the set temperature.
To:Set temperature (65~83°F) | When room temperature becomes 4 degrees above the set temperature,the operation mode can not be changed | ||||
for 15 minutes. |
|
|
|
| |
(degree) |
|
|
|
| |
| Mode change (HEAT | COOL) |
|
| |
|
|
|
| ||
To + 4 |
|
|
|
|
|
To + 2 |
|
|
|
|
|
To |
|
|
|
|
|
To - 2 |
|
|
|
|
|
To - 4 | 15 minutes |
|
| Mode change | |
|
|
| |||
Start |
| 15 minutes | (COOL | HEAT) | |
|
| ||||
|
|
|
|
| |
| HEAT mode | COOL mode | HEAT mode |
Compressor ON
OFF
Minimum 3 minutes
(3)Temperature range
AUTO operation is available under the outside air temperatures as follows.
0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 110 120 (°F) | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
0°F * |
|
|
|
|
|
|
|
|
|
|
|
| COOLING |
|
|
|
|
|
|
|
| 115°F | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| HEATING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 17°F |
|
|
|
|
|
|
|
| 75°F |
|
|
|
|
|
|
|
* In case of the wind baffle installed.
34