Mitsubishi Electronics PKH30FL Features, Models, Cooling capacity / Heating capacity, Seer

Models: PKH24FL PKH30FL PKH18FL PKH36FL

1 53
Download 53 pages 36.16 Kb
Page 2
Image 2
FEATURES

1

FEATURES

CHECK TEST

MODEL RUN SELECT

ModelsCooling capacity / Heating capacity FAN

SWING

NOT AVAILABLE

SEER1. COMPACT DESIGN ˚F 2. LCD WIRELESS REMOTE CONTROLLER3. AUTO FLAP SHUTTER ˚C

STOP AMPM

START4.INSTALLATION : FAST AND EASILY ADAPTABLE(1)Multi-directional piping

Indoor unit

Remote controller

Models

Cooling capacity / Heating capacity

SEER

PKH18FL

18,000 / 18,600 [25,100] Btu/h

11.1

PKH24FL

24,000 / 25,000 [31,500] Btu/h

10.2

PKH30FL

30,000 / 33,000 [40,500] Btu/h

10.6

PKH36FL

34,200 / 38,000 [45,500] Btu/h

10.5

1. COMPACT DESIGN

The PKH series models have been downsized and now require such minimal wall space that they can even be installed above windows.

2. LCD WIRELESS REMOTE CONTROLLER

The new wireless remote controller has a larger easy-to-read temperature display, and executes ON/OFF commands and temperature settings with a press of the button.

3. AUTO FLAP SHUTTER

With a simple flick of the OFF switch the air outlet can be closed off with a shutter. The shutter also functions as a flap during operation to adjust the air flow angle, with “Auto Angle 1” securing a comfortable air flow.

4.INSTALLATION : FAST AND EASILY ADAPTABLE

(1)Multi-directional piping

Multi directional drain and refrigerant piping radically improves flexibility in selecting installation layouts. PKH18/24/30/36FL models boast refrigerant piping in 4 directions and drain piping in 2 directions.

(2)Back plate installation guide

The back plate installation guide gives clear instructions on installation positions. The enlarged back plate secures the unit firmly to the wall, while the support piece which lifts the unit makes left side piping work much easier.

(3)Easily removable filter and convenient wireless remote controller

The presence of thumb screws on the filters means that the filters can be quickly and smoothly removed.

5.HIGH RELIABILITY AND EASY SERVICING

In addition to the self-diagnostic function, units are also equipped with a 3-minute time delay mechanism (cooling), an auto restart function, an emergency operation function, a test run switch, etc., to assure high reliability and easy servicing.

6. NITROGEN GAS IS CHARGED TO INDOOR UNIT

Indoor unit and refrigerant pipes are charged with nitrogen gas (N2) instead of R22 before shipment from the factory.

2

Page 2
Image 2
Mitsubishi Electronics PKH30FL, PKH36FL Features, Models, Cooling capacity / Heating capacity, Seer, Compact Design