CHIMNEY INSTALLATION

FIGURE 15

CENTERLINE

OF CHIMNEY

FIGURE 16

ACTUAL CENTER POINT

PLUMB LINE

PLUMB BOB

IMAGINARY CENTER POINT

TABLE 1

MINIMUM REQUIRED ROOF OPENING

MINIMUM FRAMED OPENING

ROOF PITCH

"S" SERIES DOUBLE

"E" SERIES DOUBLE

WALL CHIMNEY

WALL CHIMNEY

 

 

 

0/12

14 1/2" x 14 1/2"

17" x 17"

1 12

14 1/2" x 14 5/8"

17" x 17" 1/8"

2/12

14 1/2" x 14 3/4"

17" x 17" 1/4"

3 12

14 1/2" x 15"

17" x 17" 1/2"

4/12

14 1/2" x 15 1/4"

17" x 17" 3/4"

5 12

14 1/2" x 15 3/4"

17" x 18" 1/4"

6/12

14 1/2" x 16 1/4"

17" x 18" 3/4"

7 12

14 1/2" x 16 7/8"

17" x 19" 3/8"

8/12

14 1/2" x 17 1/2"

17" x 20"

9 12

14 1/2" x 18 1/8"

17" x 20" 5/8"

10/12

14 1/2" x 18 7/8'

17" x 21" 3/8"

11 12

14 1/2" x 19 3/4"

17" x 22" 1/4"

12 12

14 1/2" x 20 1/2"

17" x 23"

 

 

 

INSTALLATION OF FIRESTOP-SPACER AT ATTIC LEVEL

 

INLET AIR PIPE

FIGURE 17

CEILING JOIST

FLUE PIPE

 

 

 

OUTER PIPE

FLUE

SUPPORT STRAPS

FASTEN SECURELY

FIRESTOP

CHIMNEY

SUPPORT

SNAP LOCK CHIMNEY

SUPPORT SECURLY

TO LOWER PIPES

BEFORE FASTENING

SUPPORT STRAPS

16

FIRESTOP SPACER

HEADER

CHIMNEY SECTION

INSTALLATION OF FIRESTOP-SPACER AT FLOOR LEVELS

INLET AIR PIPE

FLUE PIPE

FLOOR JOIST

FIRESTOP SPACER HEADER

CHIMNEY SECTION

53D9031. Rev 1 03/03