FIREPLACE LOCATION

CAUTION: Do not install fireplace over carpeting.

This fireplace does not weigh more than large pieces of furniture and can normally be located near a load bearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmed with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.

Figures 4 and 5 provide dimensional details of the fireplace, required spacing to combustible walls, and some suggested fireplace locations. When selecting a location, choose one that is away from frequently opened doors, central heat outlets or returns, or other places where air movements may disturb the airflow around the fireplace. Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.

FIGURE 4

50 9/16" MIN.

13 3/4"

MIN.

71 1/2" MIN.

133/4"

MIN.

21 1/2" MIN.

FRAMING DIM.

23" MIN.

24" MIN.*

55" MIN.

(WITH GLASS DOORS INSTALLED)

NOTE: Combustible side wall clearance may be reduced by 12" if the fireplace is provided with the GD42B or GD42PB glass door assembly.

CORNER INSTALLATION

SIDE WALL INSTALLATION

FIGURE 5

FULL PROJECTION

CORNER

FLUSH

7

53D9032. Rev 1 03/03

Page 47
Image 47
Monessen Hearth BWB400I, BWBC400I manual Corner Installation Side Wall Installation