FIREPLACE COMPONENTS

SEE FIGURE 13 FOR ILLUSTRATION OF FIREPLACE COMPONENTS DESCRIBED BELOW.

MODEL

DESCRIPTION

SF36A

36-inch radiant fireplace.

SF36AI

36-inch insulated radiant fireplace.

SCF36A

36-inch circulating fireplace.

SCF36AI

36-inch insulated circulating fireplace.

GD36PB

Optional 36-inch polished brass bifold glass door kit. Frame has polished brass finish; tempered glass is clear.

GD36B

Optional 36-inch black bifold glass door kit. Frame has black finish; tempered glass is clear.

SCS

Chimney support. (Required when chimney height exceeds 30 feet.)

SE30

Elbow offset/return package containing two 8-inch diameter 30-degree elbows.

6120 to 6/12 variable pitch roof flashing. One 612 flashing required with SC round chimney cap on 0 to 6/12 pitch roof.

1212

6/12 to 12/12 variable pitch roof flashing. One 1212 flashing required with SC round chimney cap on 6/12 to 12/12

 

pitch roof.

SC

Round chimney cap for contemporary installation; includes storm collar.

SF

14-1/2" firestop spacer. One required at each ceiling or floor level.

SCL

Round chimney cap with telescoping pipe and storm collar. For chase installation.

SQ8

Square termination chimney cap (18-1/2" x 18-1/2") for chase installation. Use with VFK flashing kit.

SF30

Firestop spacer for 30-degree chimney incline through ceiling or floor.

H1652

16-inch x 52-inch hearth extension for protecting floor against sparks and radiant heat.

AK4

4-inch diameter outside combustion air kit. Allows air from outside to enter fireplace. (For residential homes.)

AK6

6-inch diameter outside combustion air kit. Allows air from outside to enter fireplace. (For manufactured homes.)

FP4U

4-inch diameter x 8-feet long flexible uninsulated combustion air duct. Use with AK4 kit.

FP6U

6-inch diameter x 8-feet long flexible uninsulated combustion air duct. Use with AK6 kit.

403

4-inch duct connector for splicing FP4U ducts. (Includes one connector and two clamps.)

603

6-inch duct connector for splicing FP6U ducts. (Includes one connector and two clamps.)

FA2

Optional fan kit, with switch. The FA2 fan installs behind the lower grille of the SCF36A and SCF36AI fireplaces.

 

(For SCF36A and SCF36AI fireplaces.)

JB1

Junction box - For Optional FA2 Fan installation on SCF36A and SCF36AI fireplaces. The JB1 junction box must

 

be installed at the time of fireplace installation if the FA2 Fan is to be installed at any time.

S8

8-inch diameter double-wall telescope pipe for use with LFSQT chimney cap.

LFSQT

Square shroud termination chimney cap for chase installation. Use with S8 telescope pipe and VFK flashing kit.

￿(Minimum chase top dimensions: 26" x 26".)

SPC

Pyramid shroud termination chimney cap for chase installation.

H36

Hood for heat deflection. Hood may be installed on fireplace in residential type home to reduce the recommended

 

clearance to a combustible mante. This hood is not for use with glass doors.

R3672

36" x 72" flat chase flashing with single flue hole.

R4884

48" x 84" flat chase flashing with single flue hole.

CF8

Terra Cotta masonry-look termination chimney cap for chase installation. Use with VFK flashing kit.

VFK

Vent flashing kit consisting of adjustable radiation shield with spacer brackets and fasteners.

 

(For venting a field-constructed flashing assembly on a combustible chase top.)

S48

48-inch long x 8-inch diameter chimney flue section.

S36

36-inch long x 8-inch diameter chimney flue section.

S18

18-inch long x 8-inch diameter chimney flue section.

S12

12-inch long x 8-inch diameter chimney flue section.

: DENOTES FIREPLACE COMPONENTS NOT ILLUSTRATED BY CORRESPONDING FIGURE.

13

53D9031. Rev 1 03/03

Page 13
Image 13
Monessen Hearth BWBC400I, BWB400I manual See for Illustration of Fireplace Components Described below