CLEARANCES
(FLUE OUTLET HEIGHT)
FIGURE 1
RESIDENTIAL INSTALLATION
| 14 FT. = MIN. HEIGHT (NO OFFSETS) | |
ROUND CHIMNEY CAP | 14 FT. = MIN. HEIGHT | |
21 FT. = MIN. HEIGHT | ||
MODEL SC | 86 FT. = MAX. HEIGHT (CHIMNEY | |
| SUPPORT EVERY 30 FT.) | |
ROOF FLASHING | STORM | |
MODEL 612 | ||
COLLAR | ||
|
1 3/4" MIN. AIR SPACE TO COMBUSTIBLES)
CHIMNEY (2" MIN. AIR SPACE
TO COMBUSTIBLES MODEL:
S12 (1 FT. PIPE)
S18 (18 IN. PIPE)
S36 (3 FT. PIPE)
S48 (4 FT. PIPE)
TOP SPACER
FLEXIBLE DUCT
TYPE
SEE NOTE
44 1/2"
FRAMING
DIMENSION
44"
FRAMING
DIMENSION
(BOTTOM OF FIREPLACE)
WARM AIR OUTLET (SEE CAUTION)
COMBUSTION AIR | GALVANIZED METAL STRIP | |
ASSEMBLY MODEL AK4 | ||
|
| GD42B/GD42PB GLASS |
| DOOR ACCESSORY |
| COOL AIR INLET (SEE CAUTION) |
21 1/2" | NAIL TO FRAMING MEMBERS |
FRONT - TO BACK |
|
FRAMING DIMENSIONS | FIREPLACE - MODEL SCF42A OR SCF42AI SHOWN |
| CAUTION: DO NOT BLOCK AIR INLETS OR OUTLETS. |
NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER.
5
53D9032. Rev 1 03/03