TRIM INSTALLATION

INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE

COMBUSTIBLE FRAMING

MEMBERS FACING MATERIAL

TO TOP OF SPACERS.

FIGURE 29

NON-COMBUSTIBLE

FACING MATERIAL USE ONLY NON-COMBUSTIBLE MATERIALS BELOW TOP OF SPACERS.

FIREPLACE FACE

 

 

WARNING:

 

THE SPACE BETWEEN THE

STEEL LINTEL

FACE OF THE FIREPLACE

(OPTIONAL)

AND THE NON-COMBUSTIBLE

 

FACING MATERIAL MUST BE

CAUTION:

SEALED. FAILURE TO

DO NOT COVER

PROPERLY SEAL THIS CRACK

OR RESTRICT SIDE VENT

CAN CAUSE A POSSIBLE FIRE

AREAS WITH SURROUND

HAZARD AND WILL VOID THE

OR TRIM MATERIALS.

WARRANTY.

INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND

COMBUSTIBLE FRAMING MEMBERS

FACING MATERIAL TO TOP OF SPACERS.

FIGURE 30

USE ONLY NON-COMBUSTIBLE

MATERIALS BELOW TOP

OF SPACERS.

1" AIR SPACE TO SIDES AND REAR OF FIREBOX

IT IS RECOMMENDED THAT YOU

INSULATE OUTER AND INNER WALLS

OF CHASE. ALWAYS MAINTAIN THE

PROPER CLEARANCE.

OUTSIDE AIR INLET

SAFETY STRIP

12" MAXIMUM

COMBUSTIBLE MANTEL

TOP EDGE OF FIREPLACE

18" MINIMUM FROM FIREPLACE OPENING TO BOTTTOM OF COMBUSTIBLE MANTEL, (MANUFACTURER RECOMMENDATION).

SEE NOTE BELOW REGARDING H2853 CANOPY.

TOP EDGE OF FIREPLACE OPENING

HEARTH EXTENSION

NOTE:

WHEN AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED IN THIS FIREPLACE, AN H2853 CANOPY MUST ALSO BE INSTALLED.

FIGURE 31

COMBUSTIBLE SURROUND MATERIALS MAY BE PLACED WITHIN SHADED AREAS. (NOTE: COMBUSTIBLE MATERIALS MUST NOT OVERLAP BLACK PAINTED SURFACE.)

OUTLINE OF

FIREPLACE

FIREBRICK

4"

(REF.)

FRAMING

EXTEND LINE FROM OPPOSITE REAR OF

FIREBOX THRU A POINT 4" IN FRONT OF

FIREPLACE FACE, AND 1" OUTSIDE OF

1/4" SCREENED OPENING.

FINISHED WALL

SCREENED OPENING

OF FIREPLACE

27

53D9032. Rev 1 03/03