GLASS DOOR INSTALLATION AND FAN ACCESSORY
GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with optional Model GD36P or GD36PB glass doors. For installation of the Models GD36P or GD36PB glass doors, see the instructions provided with the doors.
FAN ACCESSORY
The model BWBC400 and BWBC400I Fireplaces may be equipped with a Model FA2 fan accessory. If the fireplace is to be equipped with the FA2 fan at anytime, the JB1 junction box assembly must be installed on the fireplace as shown by Figures 32 and 33 during the installation of the fireplace. Unless the JB1 junction box is installed at this time, wall finishing materials must be removed to gain access to the side of the fireplace to install the JB1 junction box at a later date. Complete Installation and Operation Instructions are included with the FA2 Fan.
Note: A rectangular switch knockout is provided on the lower right hand face of the fireplace.
MODEL JBI JUNCTION BOX INSTALLATION
FIGURE 32
FASTEN MODEL JBI JUNCTION
BOX TO THE SIDE OF THE
FIREPLACE WITH THE TWO
SHEET METAL SCREWS REMOVED
FROM JUNCTION BOX
OPENING COVER.
NOTE: THE THREE PRONG RECEPTACLE
AND ITS COVER MUST BE EXPOSED AND
THE COVER PLATE MUST BE REMOVABLE
FOR INSPECTION OF WIRING CONNECTION
ONCE THE FIREPLACE IS INSTALLED.
REMOVE JUNCTION BOX COVER FROM FIREPLACE.
GAS APPLIANCE
OPENING COVER
JUNCTION BOX
OPENING COVER
BELK LOUVER KIT
FIGURE 33
M1 | M2 |
(FAN ASSEMBLIES) | CORDSET |
120V, 60HZ | |
| SWITCH |
| (SPST) |
JUNCTION BOX
OF FIREPLACE
|
| BLACK | TO FUSE OR |
|
| ||
|
| WHITE | |
|
| CIRCIUT BREAKER | |
|
|
| |
|
|
| |
|
|
|
|
| GROUND |
| |
|
|
NOTE: THE
28
53D9031. Rev 1 03/03