OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS

NOTE: The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model AK4 combustion air kit.

FIGURE 24

INSULATION RING

INSERT SHORTEST SIDE OF THE TUBE THROUGH THE FIREPLACE OUTER WRAP TO PROPERLY SEAL AGAINST FIREBOX WALL AND GASKET.

SECURING OUTSIDE AIR STARTING COLLAR TO FIREPLACE

LONGER LENGTH OF THE

TUBE TO OUTSIDE.

STEP 1: SECURE OUTSIDE AIR STARTING COLLAR TO LEFT SIDE OF FIREPLACE WITH FOUR SHEET METAL SCREWS PROVIDED.

NOTE: THE STARTING COLLAR EXTENDS THROUGH THE OUTER FIREPLACE JACKET AND WILL SEAL AGAINST THE FIREBOX WALL WHEN SECURED AS INDICATED.

STEP 2: SECURE OUTSIDE DUCT TO STARTING COLLAR WITH DUCT CLAMP OR SCREWS.

FIGURE 25

FIGURE 26

SCREWS

5" DIA. HOLE FOR AK4

COMBUSTION AIR ASSEMBLY

FOR MODEL NO. AK4

2" APP.

NAIL

DUCT

HOLES

 

INSULATION

DUCT CONNECTOR

DUCT CLAMP

INSTALLATION OF THE MODEL 403 DUCT CONNECTOR

1. Push the insulation back approximatly 2" from the end of each duct .

2.Slip each duct over the duct connector until an equal length of the connector extends into each duct.

3.Place a duct clamp over the end of each duct

and tighten it down snuggly.

4. Push the insulation back into place and over

the duct clamp.

22

53D9032. Rev 1 03/03

Page 62
Image 62
Monessen Hearth BWBC400I, BWB400I manual Outside Combustion AIR Precautions & Recommendations