COMBUSTION AIR ASSEMBLY
MODEL AK4 COMBUSTION AIR ASSEMBLY
1.Remove the cover plate from the
2.Place the insulation ring between the AK4 starting collar and fireplace wall and place the starting collar (4 inch) into the hole on the side of the fireplace. Fasten it in place with the four sheet metal screws provided. Figure 24.
3.Cut a
4.Select and cut a piece of duct sufficient length to attach to the fireplace and protrude at least three inches beyond the face of the wall to which the AK4 inlet air vent will be attached. The duct may be cut with a standard pocket knife (use
5.If the duct is the insulated type, push the insulation back from one end of the duct approximately two inches. Figure 26.
6.Slip the exposed end of the duct over the starting collar on the fireplace.
7.Using the sheet metal screws provided, secure the duct end to the collar attached to the fireplace.
8.Nail or screw the combustion air assembly to the surface of the wall.
NOTE: If the wall covering is brick or stone, use appropriate masonry fasteners. Mount the combustion air assembly with “TOP’” upward to prevent cold air from entering through the wall. If it is necessary to splice the duct, a model 403 duct connector should be used to splice duct sections.
24
53D9032. Rev 1 03/03