OPERATION GUIDELINES
supplied, this can cause a negative pressure in the home. When this happens, the house will draw in outside air from the cracks in the windows, down the fireplace flue or other locations of air leakage in the home. Because cold air infiltration may be unavoidable in some structures, Monessen Hearth Systems is not responsible for heat loss or air infiltration through or around the fireplace.
CLEARANCES
(FLUE OUTLET HEIGHT)
FIGURE 1 | RESIDENTIAL INSTALLATION |
| 14 FT. = MIN. HEIGHT (NO OFFSETS) | |
ROUND CHIMNEY CAP | 14 FT. = MIN. HEIGHT | |
21 FT. = MIN. HEIGHT | ||
MODEL SC | 86 FT. = MAX. HEIGHT (CHIMNEY | |
| SUPPORT EVERY 30 FT.) | |
ROOF FLASHING | STORM | |
MODEL 612 | ||
COLLAR | ||
|
1 3/4" MIN. AIR SPACE TO COMBUSTIBLES)
CHIMNEY (2" MIN. AIR SPACE
TO COMBUSTIBLES MODEL:
S12 (1 FT. PIPE)
S18 (18 IN. PIPE)
S36 (3 FT. PIPE)
S48 (4 FT. PIPE)
TOP SPACER
FLEXIBLE DUCT
TYPE
SEE NOTE
38 1/2"
FRAMING
DIMENSION
37 3/4"
FRAMING
DIMENSION
(BOTTOM OF FIREPLACE)
WARM AIR OUTLET (SEE CAUTION)
COMBUSTION AIR | GALVANIZED METAL STRIP | |
ASSEMBLY MODEL AK4 | ||
|
| GD36B/GD36PB GLASS |
| DOOR ACCESSORY |
| COOL AIR INLET (SEE CAUTION) |
21 1/2" | NAIL TO FRAMING MEMBERS |
FRONT - TO BACK |
|
FRAMING DIMENSIONS | FIREPLACE - MODEL SCF36A SHOWN |
| CAUTION: DO NOT BLOCK AIR INLETS OR OUTLETS. |
NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER.
SUCH AS BRICK OR TILE MAY BE USED TO TRIM FACE OF THE FIREPLACE BUT SHOULD NOT COVER ANY PORTION OF THE LOUVERED PANEL OR COOL AIR INLET. COMBUSTIBLES MUST NOT OVERLAP THE BLACK PAINTED FACE OF FIREPLACE.
5
53D9031. Rev 1 03/03