TRIM INSTALLATION
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints of masonry trim.
FIGURE 31
COMBUSTIBLE FRAMING
MEMBERS FACING MATERIAL
TO TOP OF SPACERS.
PART A
| |
FACING MATERIAL | USE ONLY |
| MATERIALS BELOW TOP OF SPACERS. |
FIREPLACE FACE |
|
| WARNING: |
| THE SPACE BETWEEN THE |
STEEL LINTEL | FACE OF THE FIREPLACE |
(OPTIONAL) | AND THE |
| FACING MATERIAL MUST BE |
CAUTION: | SEALED. FAILURE TO |
DO NOT COVER | PROPERLY SEAL THIS CRACK |
OR RESTRICT SIDE VENT | CAN CAUSE A POSSIBLE FIRE |
AREAS WITH SURROUND | HAZARD AND WILL VOID THE |
OR TRIM MATERIALS. | WARRANTY. |
PART B
COMBUSTIBLE SURROUND MATERIALS MAY BE PLACED WITHIN SHADED AREAS. NOTE: COMBUSTIBLE MATERIALS MUST NOT OVERLAP BLACK PAINTED SURFACE MORE THAN 1/8".)
COMBUSTIBLE FRAMING MEMBERS TO TOP OF SPACERS
PART C
TOP SPACER
OUTLINE OF |
| FRAMING |
| EXTEND LINE FROM OPPOSITE REAR OF | |
FIREPLACE |
| |
| FIREBOX THRU A POINT 4" IN FRONT OF | |
FIREBRICK |
| |
| FIREPLACE FACE, AND 1" OUTSIDE OF | |
|
| |
| 1/4" | SCREENED OPENING. |
|
| |
|
| FINISH WALL |
4" | SCREENED OPENING |
|
(REF.) |
| |
OF FIREPLACE |
| |
|
|
12" MAX.
COMBUSTIBLE MANTEL
COMBUSTIBLE SURROUND TRIM
|
| ** | : 12" MINIMUM FROM TOP OF FIREPLACE OPENING TO BOTTOM OF |
| ** | COMBUSTIBLE TRIM MATERIAL WHICH PROJECTS MORE THAN | |
|
| BEYOND THE TOP OF THE FIREPLACE OPENING. | |
|
|
| |
* |
| * | : 6" MINIMUM FROM TOP OF FIREPLACE OPENING TO BOTTOM OF |
| COMBUSTIBLE TRIM MATERIAL WHICH PROJECTS NO MORE THAN | ||
|
TOP OF FIREPLACE OPENING
INSTALLATION OF COMBUSTIBLE TRIM MATERIALS
ABOVE THE TOP OF THE FIREPLACE OPENING
PART C OF FIGURE 31 SHOWS ACCEPTABLE COMBUSTIBLE MANTEL LOCATION IF FIREPLACE IS INSTALLED TO BURN WOOD. SEE FIGURES 29 AND 30 FOR ACCEPTABLE COMBUSTIBLE MANTEL LOCATIONS IF AN UNVENTED GAS APPLIANCE IS INSTALLED IN THE FIREPLACE. PARTS A AND B OF FIGURE 31 ARE TYPICAL FOR EITHER WOOD OR UNVENTED GAS APPLIANCE INSTALLATION.
27
53D9031. Rev 1 03/03