INSTRUCTION OR MESSAGE

LS600 PUMP — DIGITAL READOUT SCREEN

PRIMARY SCREEN

Screen 1

Indicates the various modes of the switch settings. Monitors engine RPM - Idle speed 900, High speed 2550. Battery charge indicator - Normal charge 13+ volts. Indicates electrical malfunction - Refer to Troubleshooting section.

Screen 5

Displays the ON/OFF electrical signal status of the various 12 volt solenoids (Swing A circuit, Main A circuit, Main B circuit).

INDICATES

 

 

 

 

SWING A

 

 

 

 

CIRCUIT IS OFF

 

 

 

 

 

SWING A OFF

5

 

 

 

 

 

 

 

 

MAIN A OFF

 

 

 

INDICATES

 

MAIN B OFF

 

 

INDICATES

 

 

 

 

MAIN B

 

 

 

 

MAIN A

 

 

 

 

CIRCUIT IS OFF

 

 

 

CIRCUIT IS OFF

SECONDARY SCREENS

Screen 2

DisplaysthepositionoftheVOLUMECONTROLswitchbyindicating whether the increase or decrease position is on or off.

Screen 6

Displays the ON/OFF electrical signal status for the Proximity Switch A, Proximity Switch B, Engine Fuel Solenoid, and Unloader Solenoid.

INDICATES

 

 

 

INDICATES

PROXIMITY A

 

 

 

 

PROXIMITY B

CIRCUIT IS OFF

 

PROX A OFF

6

 

CIRCUIT IS ON

 

 

 

 

 

 

PROX B ON

 

 

 

 

 

FUEL SOL OFF

 

 

 

INDICATES

 

UNLOADER OFF

 

 

INDICATES

 

 

 

 

 

 

UNLOADER

 

 

 

FUEL SOLENOID

CIRCUIT IS OFF

 

 

 

CIRCUIT IS OFF

INDICATES VOLUME SWITCH IS NOT IN THE - POSITION

FLOW DEC OFF 2

FLOW INC ON

INDICATES VOLUME SWITCH IS IN THE + POSITION

Screen 7

Displays the number of times the main hydraulic cylinders stroke and the yards per hour output. This indicator can be reset to zero by the RESET switch on the control panel.

Screen 3

INDICATES

 

 

THROTTLE

 

 

IS ON

THROTTLE ON

7

 

 

STROKES: 20

 

INDICATES THE NUMBER OF STROKES

Displays the number of hours the engine and pump have been used and the number of faults the pump has registered. All three indicators can be reset to zero by the RESET switch on the control panel.

 

 

STROKES/MIN 8.2

 

INDICATES THE

YDS/HR 10.7

 

 

 

 

 

 

NO. OF YARDS

 

 

 

PER HOUR

 

 

INDICATES THE NO. OF STROKES PER MINUTE

Screen 8

INDICATES NO. OF HOURS ENGINE HAS BEEN USED

MESSAGE OR INSTRUCTION

E HRS: 00000.0 3

PMP HRS: 00000.0

FAULTS: 00000000 RESET TO CLEAR

INDICATES NO. OF HOURS PUMP HAS BEEN USED

INDICATES NO. OF FAULTS DETECTED

Displays the electrical status of the engine fuel solenoid. To test the 12-Volt solenoid status, activate with the RESET switch on the control panel.

8

TO TEST FUEL SOL PRESS RESET FUEL SOL OFF

Screen 4

Displays the number of strokes the main hydraulic cylinders have gone through. This indicator can be reset to zero by the RESET switch on the control panel.

INDICATES THE

FUEL SOLENOID

IS OFF

Screen 9

Displays the communication status of the (optional) radio remote control.To activate a new remote control connection,

INDICATES A RUNNING COUNT OF NO. OF STROKES

4 STROKE CTR: 0000

PRESS RESET TO ZERO STROKE CTR

use the reset switch on the control panel.

 

 

 

INDICATES

 

 

 

THAT RADIO

 

 

 

 

RADIO ADDRESS 9

 

REMOTE IS ON

 

COMMUNICATING

 

 

 

PRESS RESET TO

 

 

 

LEARN A NEW ONE

 

 

MESSAGE OR INFORMATION

IINSTRUCTION

OR MESSAGE

MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11) — PAGE 21

Page 21
Image 21
Multiquip manual LS600 Pump Digital Readout Screen, Primary Screen

LS600 specifications

The Multiquip LS600 is a robust and efficient light tower designed to provide reliable lighting solutions for various applications, including construction sites, outdoor events, and emergency services. This advanced model blends cutting-edge technologies with user-friendly features, ensuring that users have the illumination needed to get the job done safely and effectively.

At the heart of the LS600 is its powerful lighting system, which utilizes four high-efficiency LED lights. These lights deliver an impressive total output of up to 600,000 lumens, providing extensive coverage and bright illumination across large areas. The energy-efficient LEDs not only offer superior brightness but also contribute to lower operational costs and extended run times compared to traditional lighting systems.

One of the standout features of the LS600 is its extendable mast. The mast can be raised to a height of 30 feet, allowing the lights to be positioned at an optimal height for maximum visibility. This flexibility is essential for overcoming obstacles and ensuring that all areas are uniformly lit. The mast is also designed for quick and easy deployment, enabling users to set up the light tower rapidly and focus on their primary tasks.

The LS600 is powered by a reliable and fuel-efficient diesel engine, which provides consistent performance even in demanding conditions. The engine is equipped with advanced technologies to enhance fuel efficiency and reduce emissions, making it an environmentally friendly option for users who are conscious of their carbon footprint. The light tower has a long run time, capable of operating for extended periods without the need for frequent refueling.

Portability is another key characteristic of the Multiquip LS600. The unit is designed with a rugged frame and sturdy wheels, allowing for easy transport across various terrains. This mobility is complemented by a compact design that facilitates storage and handling, making it an ideal choice for rental companies and contractors.

In conclusion, the Multiquip LS600 stands out as a versatile and powerful light tower, engineered to deliver exceptional performance and reliability. Its high-lumen LED lighting, extendable mast, robust diesel engine, and portability make it a top choice for those in need of dependable lighting solutions in challenging conditions. Whether illuminating a busy construction site or enhancing safety at an outdoor event, the LS600 is equipped to handle a wide range of lighting demands with efficiency and ease.