LS600 PUMP — TROUBLESHOOTING (ELECTRICAL)
TABLE 12. ELECTRICAL TROUBLESHOOTING (continued)
MALFUNCTION |
|
| |
READING | PROBABLE CAUSE | SOLUTION | |
(Screen 1) |
|
| |
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
| read 6 ohms. Replace burnt solenoid. | ||
THROTTLE SOLENOID |
| ||
|
| ||
OPEN |
|
| |
| Wire connection broken. | Replace broken wire. | |
|
|
| |
| The | Measure solenoid coil resistance. It should | |
THROTTLE SOLENOID | directly to ground. | read 6 ohms. Replace shorted solenoid. | |
|
| ||
SHORTED | Wire connection is shorted directly to the |
| |
| Correct connection. | ||
| ground. | ||
|
| ||
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
| read 6 ohms. Replace burnt solenoid. | ||
|
| ||
FUEL SOLENOID OPEN |
|
| |
Wire connection broken. | Replace broken wire. | ||
| |||
|
|
| |
| The | Measure solenoid coil resistance. It should | |
FUEL SOLENOID | directly to ground. | read 6 ohms. Replace shorted solenoid. | |
|
| ||
SHORTED | Wire connection is shorted directly to the |
| |
| Correct connection. | ||
| ground. | ||
|
| ||
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
| read 6 ohms. Replace burnt solenoid. | ||
UNLOADER SOLENOID |
| ||
|
| ||
OPEN |
|
| |
| Wire connection broken. | Replace broken wire. | |
|
|
| |
| The | Measure solenoid coil resistance. It should | |
UNLOADER SOLENOID | directly to ground. | read 6 ohms. Replace shorted solenoid. | |
|
| ||
SHORTED | Wire connection is shorted directly to the |
| |
| Correct connection. | ||
| ground. | ||
|
| ||
|
|
| |
ALTERNATOR FAILURE | Defective alternator. | Replace alternator. | |
|
|
| |
Engine blower cooling fan | Replace | ||
requiring replacement. | |||
|
| ||
|
|
|
PAGE 68 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)