REMOTE CONTROL (OPTIONAL)

REMOTE CONTROL (OPTIONAL)

The LS600 Concrete Pump has a remote control feature that allows the pump to be remotely controlled. If desired, the pump can be operated via a receiver/transmitter (radio) or a hardwire method, which utilizes a 25-ft. extension cable. Contact MQ Sales Department to order remote control.

LS600 PUMP — OPERATION

4.Reinstall the control panel and tighten the 2 screws.

5.On the top of the unit, to the right of the control box (Figure 36), hammer out the knock-out hole and install the remote antenna.

Radio Remote Control

Installation of the Radio Remote Control Assembly

1.Remove the two screws on the digital control panel of the pump. See Figure 33.

CONTROL BOX

VOLUME

DIRFELOW

CTION

CONTROL

ON

 

OFF

 

START

 

IGNITION

REMOTE

ANTENNA

KNOCK-OUT

HOLE Radio Remote ControlRadio Remote Control Buttons Operation

ANTENNA

CONNECTOR

CABLE

REAR OF CONTROL BOX

CONTROL BOX CONNECTOR

REMOVE 2 SCREWS

Figure 33. Removing Screws from Control Panel

2.Tilt and slowly pull out the control panel and place on top of box to gain access inside the box. See Figure 34.

Figure 34. Pulling Out Control Panel

3.Install the wireless remote module with the 2 screws and nuts provided inside the control panel. Connect the 3-wire connector from the wireless remote module to the electronic control unit. See Figure 35.

Figure 36. Antenna Installation

6.Connect the antenna cable to the connector on the rear of the control box (Figure 36).

Radio Remote Control Buttons Operation

The pumping operation can be performed by radio remote control (Figure 37). Before using remote control, move the Pumping Control Switch on the control box to the REMOTE position.The buttons on the remote control have the following functions.

ON/OFF - Turns the power on or off. When power is on the power LED lights red. If the battery LED turns red, 9V battery needs to be replaced.

E-STOP- Turns off the pump completely in an emergency.

PUMP ON/OFF - Starts and stops the forward pumping.

PUMP REV - momentarily pumps in reverse direction.

VOLUME (+) - used to increase the pumping volume.

VOLUME (-)- used to decrease the pumping volume.

SCREWS AND NUTS

E-STOP

ON

ELECTRONIC

OFF

PUMP PUMP

POWER LED

CONTROL

UNIT

WIRELESS

REMOTE

MODULE

CONNECTOR

REV ON/OFF

BATTERY LED

VOLUME VOLUME

NOTE: OLDER MODELS

MAY INDICATE FLOW

INSTEAD OF VOLUME

Figure 35. Installing Remote Control Module

Figure 37. Radio Remote Control

PAGE 30 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)