LS600 PUMP — TROUBLESHOOTING (ELECTRICAL)
Refer to Figure 61 for the location of components for troubleshooting.
TABLE 12. ELECTRICAL TROUBLESHOOTING
MALFUNCTION |
|
| |
READING | PROBABLE CAUSE | SOLUTION | |
(Screen 1) |
|
| |
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
MAIN A OPEN | read 6 ohms. Replace burnt solenoid. | ||
| |||
|
| ||
|
|
| |
| Wire connection broken. | Replace broken wire. | |
|
|
| |
| The | Measure solenoid coil resistance. It should | |
MAIN A SHORTED | ground. | read 6 ohms. Replace shorted solenoid. | |
|
| ||
| Wire connection is shorted directly to the ground. | Correct connection. | |
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
| read 6 ohms. Replace burnt solenoid. | ||
|
| ||
MAIN B OPEN |
|
| |
Wire connection broken. | Replace broken wire. | ||
| |||
|
|
| |
| The | Measure solenoid coil resistance. It should | |
| ground. | read 6 ohms. Replace shorted solenoid. | |
MAIN B SHORTED |
|
| |
Wire connection is shorted directly to the ground. | Correct connection. | ||
| |||
|
|
| |
| Burnt 12 V cycling solenoid. | Measure solenoid coil resistance. It should | |
| read 6 ohms. Replace burnt solenoid. | ||
|
| ||
SWING OPEN |
|
| |
Wire connection broken. | Replace broken wire. | ||
| |||
|
|
| |
| The | Measure solenoid coil resistance. It should | |
| ground. | read 6 ohms. Replace shorted solenoid. | |
SWING SHORTED |
|
| |
Wire connection is shorted directly to the ground. | Correct connection. | ||
| |||
|
|
|
MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11) — PAGE 67