The hydraulic troubleshooting procedures listed below are intended for use by individuals equipped with the proper tools and equipment and are familiar with hydraulic systems and safe shop practices. Use the Pump Troubleshooting Table (Table 8) to identify possible causes for the pump’s malfunction. Contact the Multiquip Service department for the proper repair procedure.

DANGER - AMPUTATION RISK

During routine maintenance or removing material blockage, you will be required to put your hand in the concrete cylinders or near the shuttle tube.You are at EXTREME RISK of injury or AMPUTATION if the engine is running or if pressure is in the hydraulic system.

Prior to performing any maintenance on the pump, follow described lock out-tag out procedures. Stop the engine by turning off the ignition switch and remove the starter key. Place a “DO NOT OPERATE” tag over the switch and disconnect the battery. The pressure reading on the

accumulator pressure gauge MUST read ZERO. ALWAYS make sure the accumulator circuit pressure reads

zero prior to performing any maintenance on the pump.

WARNING - HYDRAULIC SYSTEM HAZARD

DO NOT open hydraulic lines or loosen hydraulic fittings while the engine is running! Hydraulic fluid under pressure can penetrate the skin, blind, cause burns or create other potentially dangerous hazards.

TABLE 9. PUMP TROUBLESHOOTING

Problem

Possible Problem

To Troubleshoot

 

 

 

 

Incorrect System Operating

Check the pump pressure gage. Verify

 

Pressure

it is approx. 4400 PSI

 

 

 

 

Incorrect Engine RPM setting

Verify the engine's high RPM speed is

Main Hydraulic Cylinder will

set to 2550

 

 

 

not cycle

Contaminated Main Relief Valve

Check the manifold for a contaminated

 

 

Relief Valve

 

 

 

 

 

 

Obstructed Material Cylinders

check for obstructions (dried material)

 

inside the cylinders

 

 

 

 

 

 

Incorrect Directional Control

Verify the Directional Control operating

 

Operating Pressure

pressure is approx. 1000 PSI

 

 

 

 

Contaminated Relief Valve

Check the manifold for a contaminated

Hopper Remix Paddles will

Relief Valve

 

 

 

not rotate

Broken Shaft Coupler Key

Check the Hopper Remixer shaft

 

 

coupler for a broken key

 

 

 

 

 

 

Loose Shaft Retaining Set Collar

Check the Shaft Retaining Set Collar

 

for tightness

 

 

 

 

 

PAGE 62 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)