Multiquip LS600 PUMP — MAINTENANCE PUMP, Cylinder Lubrication Box, Caution - Safety Guidelines

Models: LS600

1 152
Download 152 pages 47.02 Kb
Page 39
Image 39
CYLINDER LUBRICATION BOX

LS600 PUMP — MAINTENANCE (PUMP)

CYLINDER LUBRICATION BOX

WARNING - FREEZING CONDITIONS

When using the pump during freezing conditions, completely drain the water box and cover the hopper after pumping. Frozen liquid will restrict the piston travel and cause severe damage to the pump.

CAUTION - SAFETY GUIDELINES

Before checking lubrication level, follow lock out-tag out procedures.Stop the engine and remove the engine starter key.

1.The lubrication level should be checked everyday prior to pumping and maintained at a height of 5 inches or about ½ the concrete cylinder height. We recommend using a 30-weight motor oil.

2.As the rubber piston cups naturally wear, fine cement particles will accumulate in the box. Once the concrete paste reaches a height of about ½ inch from the bottom of the box, drain and clean the lubrication box.

CLEANINGTHE LUBRICATION BOX

1.Remove the top cover and the drain plug (Figure 40) located at the bottom of the box and fully drain the inside of the box.

2.Once the box is drained, start the engine and stroke the cylinder (keep hands out of box) ten to fifteen times.

3.While stroking, spray water inside of the box to thoroughly clean out all contamination (Figure 40).

4.When the box is clean replace drain plug, add new lubrication and install the top cover.

Figure 40. Cleaning the Lubrication Box

ACCUMULATOR CIRCUIT

DANGER - ACCUMULATOR CHARGING

Improper accumulator charging can result in an explosion causing serious injury or death! NEVER use oxygen or compressed air to charge the accumulator! Only qualified personal should perform this procedure. Use only dry nitrogen to charge

the accumulator. Contact your Mayco service department or your local Hydac representative for proper charging procedure.

The accumulator circuit has two functions in the hydraulic system.

The accumulator circuit furnishes the hydraulic pressure to cycle the shuttle tube.

The accumulator circuit also furnishes the pilot pressure necessary to activate the hydraulic system.

The accumulator circuit is equipped with a bladder type accumulator (Figure 41) charged with 1100 PSI of dry nitrogen.The accumulator stores one gallon of hydraulic oil, which is, under 1750 PSI of pressure.

Figure 41. Accumulator

When the pump cycles, a part of the stored oil is released to the shuttle cylinder. This pressure release assures the shuttle tube has enough force to shear the cylinder of concrete passing from the concrete cylinder to the concrete delivery line during the cycle phase.

CHECKING ACCUMULATOR BLADDER PRESSURE

The normal accumulator charge pressure should be approximately 1100 PSI. To check the accumulator pressure:

1.Start the engine and stroke the pump. The accumulator pressure gauge (Figure 30) should read 1750 PSI.

2.To determine the actual accumulator PSI, stop the engine and observe the pressure gauge. As the PSI reading slowly decreases, it will reach a point where there will be a sudden drop in the PSI.The PSI reading should be taken just prior to this sudden drop. If you do not read 1100 PSI, the accumulator may require charging or bladder replacement.

MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11) — PAGE 39