APPLYING POWER (Side View)

Unscrew & Remove the DC Voltage Input Plug from the Power Input Header

Install the DC Power Cables into the Plug (observing polarity).

Plug the Voltage Input Plug back into the Power Input Header.

Tightening torque for the terminal block power plug is 0.5 Nm/0.368 Pound Foot.

Verify the Power LED stays ON (GREEN).

Note: Only 1 power supply must be connected to power for minimal operation. For redundant power operation, V1 and V2 inputs must be connected to separate DC Voltage sources. This device will draw current from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.

Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-5

Input AC 100V…240V

Power 120W

Output DC 24V…28V

Peak Power 180W (max 4 sec.)

Output Current 5A

35 mm DIN-Rail Mountable

Peak Current 7.5A for 4 sec.

Dimensions: 1.57”W x 4.88”H x 4.61”D

5/17/2007

page 14 of 138

Page 14
Image 14
N-Tron 9000 Series user manual Applying Power Side View