Chapter 13 Multi-Loop Synthesis
Xmath Interactive Control Design Module 13-6 ni.com
Figure 13-5. Root Locus Window During the Multi-Loop Design
Figure 13-4 shows an example multiloop configuration for the 3-sensor,
2-actuator plant. There are two loops: one from sensor 1 to actuator 1,
and one from sensor 3 to actuator 2. In multiloop design you can alternate
between designing each of the (SISO) controller transfer functions, with
the other fixed.
Figure 13-5 shows an example multiloop configuration for the 3-sensor,
2-actuator plant considered, redrawn showing C(1) connected to Pequiv,
which is the plant with all other loops closed (in this case, just one other
loop). While designing C(1), it is useful to think of it as the SISO controller
for the SISO “equivalent” plant Pequiv. Again, notice that Pequiv depends on
which loop you are designing.