© National Instruments Corporation 8-1 Xmath Interactive Control Design Module
8
H-Infinity Synthesis
This chapter describes the H Synthesis window used for SISO plants.
The H Synthesis window is used to synthesize a central controller. Such
controllers are sometimes called linear exponential quadratic Gaussian
(LEQG) or minimum entropy controllers. For a description of the MIMO
Synthesis window, refer to Chapter 12, LQG/H-Infinity Synthesis.

H-Infinity Synthesis Window Anatomy

The H Synthesis window is shown in Figure 8-1. From top to bottom,
it consists of:
A menu bar with entries Special, Edit, View, and Help.
A control panel for changing the three design parameters:
–H performance level (γ)
Control cost parameter (ρ)
Sensor noise parameter (ν)
These parameters are described in greater detail later in this chapter.
A control panel used to edit the output weight transfer function
(described in the Output Weight Editing section).
A plotting area that contains four plots:
A singular value plot of the normalized closed-loop transfer
matrix along with the parameter γ, which can be grabbed and
dragged to a new value. If a lower bound on the minimal value
of γ is known, it also is displayed.
–A plot that shows the closed-loop poles.
A plot that shows the poles and zeros of the output weight transfer
function. When Weight Zero Edit is enabled, the user can grab
and drag the zeros to new locations.
A plot that shows the magnitude of the output weight transfer
function.