Chapter 12 LQG/H-Infinity Synthesis
© National Instruments Corporation 12-3 Xmath Interactive Control Design Module
descriptions are for the control cost parameter display. The noise level
display is similar in appearance.
A table with nu rows, having in each row:
A toggle button to include the input in the set of control inputs
A toggle button to include the input in the set of costed inputs,
labeled with the signal name
A slider defining the constant weight factor of the input:
A variable edit box for the same constant weight factor
Figure 12-2. LQG/H-Infinity Weights Window
A slider representing the logarithmic average of the input weights (ρu),
that is,
ρui,i1=nu
,,,
ρu
log 1
nu
-----ρui,
log
i1=
nu
=