Chapter4 CommonConfiguration Questions
©NationalInstruments Corporation 4-5 NI8171 Series User Manual
4. Map the shared CD-ROMdrive to K:.
5. Runk:\recover.bat. Follow the prompts to recover the hard drive.
Chassis Configuration
HowdoIsetuptheNI8171seriestoworkwithaPXI-1020or
PXI-1025 chassis?
The NI 8176 and NI 8175 controllers interface directly to the National
Instruments PXI-1020 and PXI-1025 chassis. The interface contains
signalst o interfaceto the chassis LCD display, IDE CDROM drive, and
PS/2 mouse and keyboard.

LCD Display

To enable/disable the LCD display for a PXI-1020 or PXI-1025 chassis:
1. Install the controller in a PXI-1020 or PXI-1025 chassis.
2. Connect a CRTmonitor to the VGA connector on the NI 8171 series
controller.
3. Poweron the chassis and enter the BIOS setup program du ring the
boot. (When the message Press <DEL> to enter SETUP appears,
press <Delete> or <Del> on the numeric keypad.The m essage
EnteringSetupappears, and the setup program is loaded after
ashort delay.)
4. In the PXI Setup menu,s etthe LCD chassis settingto the correct
value.
PXI-1020Enables the LCD display and setsthe resolution to
640 ×480.
PXI-1025Enables the LCD display for the PXI-1025 chassis
and sets the resolution to 800 ×600.
DisabledDisables the LCD display evenif th e controller is
installed in a PXI-1020 or PXI-1025 chassis.

IDE CD-ROM Drive

ThePXI-1020 and PXI-1025 chassis have integrated CD-ROM drives. The
BIOSautomatically detectsthe CD-ROM and enablesthe IDE interface.
The OS loadsdrivers toaccess the CD -ROM. Refer to the Boot Options
section for information on booting from the CD-ROM drive.