NEC GT6000 user manual Appendix xTroubleshooting, 10-3, Power Indicator, Projector Condition

Models: GT6000

1 117
Download 117 pages 46.44 Kb
Page 105
Image 105

10. Appendix

xTroubleshooting

This section helps you resolve problems you may encounter while setting up or using the projector.

Power Indicator

 

Indicator Condition

 

Projector Condition

Note

 

 

Off

 

The main power is off

 

 

 

 

 

 

 

Blinking light

 

Green blinking

 

0.5 sec ON,

The projector is getting ready to turn on.

Wait for a moment.

 

 

 

 

0.5 sec OFF

 

 

 

 

 

 

2.5 sec ON,

Off Timer or Sleep Timer is active.

 

 

 

 

0.5 sec OFF

 

 

 

 

Orange blinking

 

0.5 sec ON,

The projector is cooling down.

Wait for a moment.

 

 

 

 

0.5 sec OFF

 

 

 

 

 

 

2.5 sec ON,

On Timer is active.

 

 

 

 

0.5 sec OFF

 

 

Steady light

 

Green

 

The projector is turned on.

 

 

Orange

 

The projector is in Standby or Idle.

Status Indicator

 

 

 

 

 

 

 

 

 

Indicator Condition

 

Projector Condition

Note

 

 

Off

 

Normal

 

 

 

 

 

 

Blinking light

 

Red blinking

 

1 cycle (0.5 sec ON,

Lens hood or lamp cover error

Replace the lens hood or the lamp cover

 

 

 

 

2.5 sec OFF)

 

correctly.

 

 

 

 

2 cycle (0.5 sec ON,

Temperature error

The projector is overheated. Move the

 

 

 

 

0.5 sec OFF)

 

projector to a cooler location.

 

 

 

 

 

 

 

 

 

 

 

3 cycle (0.5 sec ON,

Power error

Power unit will not work correctly.

 

 

 

 

0.5 sec OFF)

 

 

 

 

 

 

4 cycle (0.5 sec ON,

Fan error

Cooling fan has stopped. Contact your

 

 

 

 

0.5 sec OFF)

 

dealer.

Steady light

 

Red (GT6000 only)

 

Circuit error

An error occurs in the circuit. Consult

 

 

 

 

 

 

your dealer.

 

 

Orange

 

Control key locked

You have pressed control panel key when

 

 

 

 

 

 

Control Key Lock is enabled.

 

 

Green

 

Idle condition

 

 

 

 

 

Lamp 1/2 Indicator

 

 

 

 

 

 

 

 

 

Indicator Condition

 

Projector Condition

Note

 

 

Off

 

Light off

Blinking light

 

Red blinking

 

2.5 sec ON,

Lamp has reached its end of life. Lamp

Replace the lamp.

 

 

 

 

0.5 sec OFF

replacement message will be displayed.

 

 

 

 

 

1 cycle (0.5 sec ON,

No lamp

Lamp is not installed. Turn off the power

 

 

 

 

2.5 sec OFF)

 

and install lamp.

 

 

 

 

6 cycle (0.5 sec ON,

Lamp error

Lamp fails to light. Wait a full minute and

 

 

 

 

0.5 sec OFF)

 

turn on the power again. If this will not

 

 

 

 

 

 

solve the problem, consult your dealer.

 

 

 

 

7 cycle (0.5 sec ON,

Lamp data error

Fails to read lamp data.

 

 

 

 

0.5 sec OFF)

 

Consult your dealer.

 

 

Green blinking

 

Re-firing the lamp

Wait for a moment.

 

 

Orange blinking

 

Switching from Lamp 1 to 2

Wait for a moment.

Steady light

 

Red

 

Lamp has been used beyond its limit. The

Replace the lamp.

 

 

 

 

 

projector will not turn on until the lamp

 

 

 

 

 

 

is replaced.

 

 

 

Green

 

Lamp mode is set to Normal mode

 

 

 

 

 

 

 

 

Orange

 

Lamp mode is set to Eco mode.

 

 

 

 

 

 

 

10-3

Page 105
Image 105
NEC GT6000 Appendix xTroubleshooting, 10-3, Power Indicator, Projector Condition, Status Indicator, Lamp 1/2 Indicator