8. Using On-Screen Menu

Page 2

Page 2

Filter Usage, Projector Usage, Projector ID

Signal Type, Video Type, Sync Type, Interlace, Direct Key

Page 3

Projector Information

Displays the information for your projector such as lamp usage, filter usage, version number and others. This dialog box has three pages.

Page 1

Version (BIOS/Firmware/Data/FPGA)

Test Pattern

Remaining Lamp 1 Time, Remaining Lamp 2 Time, Lamp 1 Hour

Meter, Lamp 2 Hour Meter

NOTE: The progress indicator shows the percentage of remaining bulb life.

The value informs you of the amount of lamp 1 and 2 respectively.

When the remaining lamp time reaches 0, the Remaining Lamp Time bar indica- tor changes from 0% to 100 hours and starts counting down. If the remaining lamp time reaches 0 hour, the projector will not turn on.

Type

Lamp life (H)

Model

 

 

Normal

Eco

 

 

 

 

 

 

Standard lamp

2000H

3000H

GT60LP

 

 

 

 

Extended life lamp

4500H

GT60LPS

 

 

 

 

NOTE: The Standard lamp life is typically 2000 hours in Normal mode (3000 hours in Eco mode).

The lamp life, however, may be decreased under certain conditions and the lamp could reach end of life within the specified time.

Press to display the test pattern. Pressing this button sequen- tially selects 10 test patterns for each red, green and blue.