F U N C T I O N  T E S T S
9.8.3 Test sequ enc e
Thistestsequenceis
notapplicableforcof
feemachineswith
twowirepowercords(with
outgroundpin).
Danger ofel ectr ocu tion !
Donot plug inth ecoff eemach inedu rin gthep rote ctiv eearth cont inu ity
test .
Readand obs erves afetyi nst ruc tio nsin user manu aloft esteq uip ment .
1) Connectblackmeasur ingcableto
groundpinofpowerplugwith analli
gatorclip(exampleshown: Swiss
powerplug).
Symbolicillustration
oftestequipment.
2) Switchontestequipm entandselect
protectiveearthcontinuitytes t.
Thecoffeemachine
Citiz&Cohas2test
holestocheckboth
thermoblocks.
TestholesonbottomofCitiz/Citiz&milk/Citiz&Coplatforms
3) Inserttipofredtestprobe intesthole
andtouchthermoblock.
4) Press"measure"button andreadoff
displayedresistance.
Theres ist ancem ust below ert han
0.3 Ohm.
5) Fillinmeasuredvalue(s )inatest
report.