Citizservicemanual79
R E P A I R S
• Ifpresent,disconnectground wire(15,partofthermoblockas sembly).
• Ifthethermoblockorcoreunithastobereplaced,disconnectmilkfrotherconnector
(57).Otherwisethecoreunitcanberemovedtogetherwiththisconnector(seepage
73).
• Removewatertankconnector (53,seepage71).
Ass embly chec kpo int s
• Allcoversareassembledonthe coreunit.
• Checkthatwiringbetweencor eunitandplatformisledthrou ghcablefixation(71).
• Usemarkedcableguidestolay wires.
• Checkwiringofmilkfrotherc onnector(57),seedetail.
• Checkwiringofmainsswitch (54),see"Wiringdiagramsmo delCitiz&milk,
EF 485/486"onpage124and following.
• Duringassemblyofthewater tankconnector(53)ontheplat form,eachofits3
latcheshastoengagewithan audibleclick.
Theflatreceptacleon
thegroundwirehasa
specialconnector
latching(seedetail).Press
downleveratfirst,thenpull
offreceptacle.