Citizservicemanual
60
R E P A I R S

Ass embl ych eckp oin ts

• Checkthatgasketisinserted inwatertankconnector(53) correctly.
• Duringassemblyofthewate rtankconnectorontheplatfor m,eachofits3latches
hastoengagewithanaudible click.
• Mindthedifferentdiametersof hosesforthewatertankconn ector.
8.4.3 Repla cin gma ins sw itc h
• Removewatertankconnecto rfromplatformfirst(seepag e59).
• Removebothinsulatedfaston receptaclesfrommainsswitch (54).
• Pressbladeofscrewdriverb etweenholderofmainsswitch andplatformcarefully.
Liftholderwithscrewdrivers lightly.Thenpressholderwi thmainsswitch(54)
inwardsuntilitcanberemov ed.
Thehosescan
remainonthewater
tankconnector.
Useapairofflatpli
erstopulloffinsulat
ingsleevewithrecep
tacle.