F U N C T I O N T E S T S

9.8Protective earth (PE) continuity test

9.8.1 What coffee machine has to be tested and when?

This test is only necessary

­for class 1 equipment (three­wire power cord with protective earth)

­for models Citiz & milk, EF 485/486

­after a repair whenever a general disassembly of the platform and/or core unit was performed.

9.8.2 General

Legal regulation

In case of a repair/modification of the coffee machine, the repair centre is bound by law to protect the user/consumer by

­restoring the regular condition of the appliance and

­performing the respective tests according to EN/IEC 60335­1 “Safety of household and similar electrical appliances” and national regulations (e.g. DIN VDE 0701).

Description

Protective earth continuity measurements are made between the protective earth terminal and conductive, touchable parts of the coffee machine where dangerous voltage could occur if the basic insulation was to fail.

This test assures that

­the ground (earth) connection does not have an interruption between the plug and touchable, conductive housing parts

­the permissible ground resistance of those conductive, touchable parts is less than 0.3 Ohms (with a test current of 200 mA DC).

Test equipment

Special test equipment is needed that complies with the regulations to perform protec­ tive earth continuity measurements. Detailed requirements and tolerances must be veri­ fied by your local authorities or measurement supplier in any case.

Test report

For legal reasons a repair or test report should be prepared and filed with following infor­ mation

­customer (name, address)

­type and serial number of coffee machine

­date of repair/test(s)

­performed test(s)/measuring value(s)

­used test equipment

­signature

Ask Nespresso for

recommendations about test equipment.