R E P A I R S

Loosen 4 screws (41, oval shaped head) at the bottom side of platform.

For complete removal of the core unit proceed as follows:

Remove water tank connector (53) from platform (see page 59).

Remove insulated faston receptacle of phase wire (15) from mains switch (54).

Disconnect adapter plug (15) of neutral wire.

If present, disconnect ground wire (15, part of thermoblock assembly).

After this repair step the core unit can be pulled out of the plat­ form slightly (with still con­ nected hoses and wires). Now the covers of the core

unit can be removed.

The hoses can remain on the water tank connector.

Use apair of flat pliers

to pull off insulating sleeve with recepta­ cle.

The flat receptacleon the ground wire has a special connector

latching (see detail). Press down lever at first, then pull off receptacle.