Depending on core unit range, refer to "Disassembly of core unit, Crange" on page 91
or "Disassembly of core unit, Drange" on page 109.
Thepressureadapter must sit firmly in the capsule bay.
F U N C T I O N T E S T S
9.4.1 Preparations
1)Remove left side panel of core unit.
2)Insert core unit back into platform.
3)Fill and insert water tank.
4)Insert connecting unit of pressure adapter into capsule bay. Push back sealing cone into capsule cage.
5)Insert fixation unit of pressure adapter into capsule bay.
6)Press down operating lever.
7)Connect pressure hose to pressure tester.
8)Place a measuring cup under the drain hose of the pressure tester.
134Citiz service manual